            [1]劉雲鵬,程槐號,胡 煥.頻率響應複數值在電力變壓器故障診斷中的應用[J].高壓電器,2019,55(07):10-14,26.[doi:10.13296/j.1001-1609.hva.2019.07.002]
             LIU Yunpeng,CHENG Huaihao,HU Huan.Application of the Complex Values of the Frequency Response in Fault Diagnosis of Power Transformer[J].High Voltage Apparatus,2019,55(07):10-14,26.[doi:10.13296/j.1001-1609.hva.2019.07.002]
            點擊複制

            頻率響應複數值在電力變壓器故障診斷中的應用()
            分享到:

            《高壓電器》[ISSN:1001-1609/CN:61-11271/TM]

            卷:
            第55卷
            期數:
            2019年07期
            頁碼:
            10-14,26
            欄目:
            研究與分析
            出版日期:
            2019-07-31

            文章信息/Info

            Title:
            Application of the Complex Values of the Frequency Response in Fault Diagnosis of Power Transformer
            作者:
            劉雲鵬 程槐號 胡 煥
            (華北電力大學河北省輸變電設備安全防禦重點實驗室, 河北 保定 071003)
            Author(s):
            LIU Yunpeng CHENG Huaihao HU Huan
            (Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Hebei Baoding 071003, China)
            關鍵詞:
            變壓器 繞組變形 頻率響應法 相位 故障診斷
            Keywords:
            transformer winding deformation FRA phase fault diagnosis
            DOI:
            10.13296/j.1001-1609.hva.2019.07.002
            摘要:
            頻率響應分析法是現場用于檢測電力變壓器內部機械缺陷的重要方法。目前有幾種不同的、用于分析頻率響應法結果的方法,其中最常用的就是利用數值指標(如相關系數、均方差等)得出不同頻響曲線之間的差異性。然而,傳統的數值指標都只使用了頻率響應結果的幅值,其對于變壓器繞組微小變形的檢測靈敏度不夠理想。因此,文中提出了一種同時考慮頻率響應結果幅值和相位的數值指標及一種改進傳統數值指標的方法;然後通過實驗得到了不同軸向微小變形程度繞組的頻率響應數據;最後將不同的數值指標應用于實驗所得數據並進行了對比試驗,驗證了所提出數值指標及改進數值指標的優越性。試驗結果表明,同時考慮頻率響應結果幅值和相位可以提高頻率響應分析法對于繞組微小變形的檢測靈敏度,有利于提高電力變壓器故障診斷水平。
            Abstract:
            Frequency response analysis (FRA) is an important technique for detecting the mechanical defects inside a power transformer. There are several methods to interpret the FRA results, and the most common method is using the numerical index (such as correlation coefficient, mean square deviation, etc) to obtain the degree of deviation between different frequency response curve. However, the traditional numerical indices use only the magnitude response of the FRA results, which is not accurate enough for the detection of minor winding deformations. Therefore, a numerical index considering both the amplitude and phase of frequency response results and a method to improve the traditional numerical index are proposed. Then the frequency response data of different axial minor deformation windings are obtained through experiments. Finally, different numerical indices are applied to the experimental data and the results are compared to verify the superiority of the proposed numerical indices and the improved numerical indices. The results show that, the sensitivity of the frequency response analysis method to the minor winding deformations could be improved by considering both magnitude response and phase response of the FRA results, which is beneficial to improve the level of power transformer fault diagnosis.

            參考文獻/References:

            [1] 郭新辰,宋 瓊,樊秀玲. 基于半監督分類方法的變壓器故障診斷[J]. 高電壓技術,2013,39(5):1096-1100. GUO Xinchen, SONG Qiong, FAN Xiulin. Transformer fault diagno-sis based on semi-supervised classifying method[J]. High Voltage Engineering, 2013, 39(5): 1096-1100.
            [2] BAGHERI M, NADERI M S, BLACKBURN T, et al. Frequency response analysis and short-circuit impedance measurement in detection of winding deformation within power transformers[J]. IEEE Electrical Insulation Magazine, 2013, 29(3): 33-40.
            [3] DICK E P, ERVEN C C. Transformer diagnostic testing by frequency response analysis[J]. IEEE Transactions on Power Delivery,1978, 97(6): 2144-2153.
            [4] BAGHERI M, PHUNG B T, BLACKBURN T. Transformer frequency response analysis: mathematical and practical approach to interpret mid-frequency oscillations[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2013,20(6):1962-1970.
            [5] GOMEZ-LUNA E, APONTE MAYOR G, GONZALEZ-GARCIA C,et al. Current status and future trends in frequency-response analysis with a transformer in service[J]. IEEE Transactions on Power Delivery,2013,28(2):1024-1031.
            [6] MITCHELL S D,WELSH J S,Modeling power transformers to support the interpretation of frequency-response analysis[J]. IEEE Transactions on Power Delivery,2011,26(4):2705-2717.
            [7] 桂峻峰, 高文勝, 談克雄. 用結構參數法研究變壓器繞組變形判據[J]. 清華大學學報(自然科學版), 2004, 44(1):93-96. GUI Junfeng, GAO Wensheng, TAN Kexiong. Criterion for transformer winding deformation calculated by thestructural parameter method[J]. Journal of Tsinghua University (Science and Technology), 2004, 44(1):93-96.
            [8] GHANIZADEH A J, GHAREHPETIAN G B. ANN and cross-correlation based features for discrimination between electrical and mechanical defects and their localization in transformer winding[J]. IEEE Transactions on Deelectrics and Electrical Insulation, 2014,21(5):2374-2382.
            [9] RAHIMPOUR E, TENBOHLEN S. Experimental and theoretical investigation of disc space variation in real high-voltage windings using transfer function method[J]. IET Electric Power Applications,2010,4(6):451-461.
            [10] 朱明林, 朱子述. 正交多項式辨識變壓器傳遞函數及其在繞組變形診斷中的應用[J]. 上海交通大學學報, 2001, 35(8):1233-1237. ZHU Minglin, ZHU Zishu. Transfer function identification using orthogonal polynomialsand its application to diagnosis of thetransformer winding deformation[J]. Journal of Shanghai Jiao Tong University, 2001, 35(8):1233-1237.
            [11] BIGDELI M, VAKILIAN M, RAHIMPOUR E. A new method for detection and evaluation of winding mechanical faults in transformer through transfer function measurements[J]. European Transactions on Electrical Power,2013,23(3):392-404.
            [12] 馬繼先, 郭東升. 變壓器繞組變形判據的研究[J]. 華北電力技術, 1998(7):6-8. MA Jixian, GUO Dongsheng. Study on deformation criterion of transformer winding[J]. North China Electri Power, 1998(7):6-8.
            [13] RAHIMPOUR E, JABBARI M, Tenbohlen S. Mathematical comparison methods to assess transfer functions of transformers to detect different types of mechanical faults[J]. IEEE Transactions on Power Delivery,2010,25(4):2544-2555.
            [14] BIGDELI M, VAKILIAN M, RAHIMPOUR E. Transformer winding faults classification based on transfer function analysis by support vector machine[J]. IET Electric Power Applications,2012,6(5),268-276.
            [15] NIRGUDE P M, ASHOKRAJU D, RAJKUMAR A D,et al. Application of numericalevaluationtechniques for interpreting frequency response measurements in power transformers[J]. IET Science, Measurement & Technology,2008,2(5):275-285.
            [16] WANG Z D, GUI J F, TAN K X, et al. Simulation analysis on propagation of partial discharge pulses in single-winding transformer[J].Power System Technology, 2003, 27(4): 39-42.
            [17] 孫 翔, 何文林, 詹江楊, 等. 電力變壓器繞組變形檢測與診斷技術的現狀與發展[J]. 高電壓技術, 2016, 42(4): 1207-1220. SUN Xiang, HE Wenlin, ZHAN Jiangyang, et al. Current status and development of test and diagnostic technique of transformer winding deformation[J]. High Voltage Engineering, 2016, 42(4): 1207-1220.
            [18] POURHOSSEIN K, GHAREHPETIAN G, RAHIMPOUR E,et al. A probabilistic feature to determine type and extent of winding mechanical defects in power transformers[J]. Electric Power System Research,2012,82(1):1-10.
            [19] RAHIMPOUR E, GORZIN D. A new method for comparing the transfer function of transformers in order to detect the location and amount of winding faults[J]. Electrical Engineering,2016,88(5):411-416.
            [20] WANG M, VANDERMAAR A, SRIVASTAVA K. Evaluation of frequency response analysis data[C]//14th International Symposium on High Voltage Engineering.[S.l.]:[s.n.],2001:904-907.

            備注/Memo

            備注/Memo:
            收稿日期:2018-11-20; 修回日期:2019-01-18 基金項目:廣東電網公司科技項目(GDKJ00000021)。 Project Supported by Science and Technology Project of Guangdong Power Grid Company(GDKJ00000021).劉雲鵬(1976—),男,教授,博導,博士後,研究方向爲特高壓輸電技術、電氣設備在線檢測和外絕緣方面。 程槐號(1992—),男,碩士研究生,研究方向爲變壓器繞組變形方面。 胡 煥(1993—),男,碩士研究生,研究方向爲變壓器建模及繞組變形檢測方面。
            更新日期/Last Update: 2019-07-15